respostas

BG496521418 The BP reading is of no real use. It shows roughly the same reading +or- 5. If u reduce your age the BP will be lower! At age 70 my BP is 150-90. After reducing age to 25 the BP is correct, 120-80! If I walk on a treadmill it doesn't go up as my regular BP apparatus shows.

Útil (0)
Enviar
respostas (2)

Q: Are 18650 lithium batteries included.?

perguntado por presch sobre 2021-01-16 01:20:01

BG496521418 Yes, 2 Li ion 18650 cells mounted on the single main PCB. Cells are accessible by removing only the battery cover.

Útil (0)
Enviar
respostas (3)

Q: How to measuring range

perguntado por Dipak sobre 2022-02-18 02:20:53

BG496521418 If u are referring to the multimeter it is default Auto. Press Auto for Auto or press 'Measure-Range' for manual range. Keep pressing for each scale which will be displayed at top. Select parameter displayed on bottom of display with the F keys.

Útil (1)
Enviar
respostas (1)

Q: why only one probe for two channels? do you get a high voltage probe?

perguntado por BG611203414 sobre 2021-01-16 03:54:49

BG496521418 242 with one 60 MHz probe which is fully insulated. The sockets are also insulated. There are 2 BNC to croc clip probes in the models with signal generator.

Útil (1)
Enviar
respostas (5)

Q: batterie type are 18V Makita ?

perguntado por BG233216155 sobre 2020-08-07 12:56:14

BG496521418 It has 5 Li cells (18650) of 2000 mAH each in series. 48VF is just a deceptive model number written outside. Individual cells can be replaced by direct soldering after filing the surface. The factory way is electric welding 2 spots.

Útil (1)
Enviar
respostas (6)